Battery Testing System|Since 1998|Recruitment|Contact
Battery Testing System|Since 1998

BTS 9000 High-tech Battery Testing System

SummarySpecifications

BTS9000 For You To Find The Future Battery

Neware BTS9000 is the best ever battery tester from Neware, it came into the market with extremely high accuracy(±0.02% of FS), Amazingly quick hardware response time(≤100μs), high-speed data acquisition frequency(1000Hz) and many other industry-proven characteristics, it can tell the subtle difference of all kinds of battery materials, it helps you to find the future battery material and solution.

 

BTS9000 is mainly designed for: Battery research insitutues, universities and laboratories of battery companies.

  • 1000Hz

    Data Record Frequency

  • 0.02%

    Accuracy

  • 400μs

    Minimum Pulse Width

  • GSM

    Test Supported

  • 4

    Auto-swith Ranges

     

     

  • ≤ 100μs

    Response Time

Small Body, Powerful Functions
High Performance Battery Testing System Especially For Material Research

Applications

  • GSM Pulse Dishcharge Supported
  • IEC Standard DCIR Test Supported
  • Mainly For Material Research
  • Also Great For Cycle Life Test
  • Adapts To Coin Cell, Pouch And More

Auto-switch 4 current output ranges

BTS9000 born with 4 current output ranges: 0.1uA-150uA, 150uA-5mA, 5mA-150mA and 150mA-5A, this feature makes it possible for you to use it to test cells in wide range of capacities accurately.

More importantly, it's great to use BTS9000 to test the C-rate performance of battery cells from high to low. Let's say you want to test a cell with capacity 50mAh from 0.001C(0.05mA) up to 20C(1000mA), before BS9000 came out, you might need several testers to make this happen, but with BTS9000, the whole testing process could be executed seamlessly on the single one machine.

Each channels’ constant voltage and current source

Up to 1000Hz data record frequency

 

Maximum data record freuqncy of Neware BTS4000 is 10Hz, but when comes to BTS9000, the data record frequency could be up to 1000Hz. Why such high frequency?

The positive feedback from battery material researchers proved this is one of the most important key features of BTS900 they like the most.

 

They use the high frequency of BTS9000 to catch even the minimal changes during the test, by doing this, they can tell exactly the characteristic of the certain material they are studying.

 

And the IEC standard DCIR function of BTS9000 is also based on the high frequency data record, with higher data record frequency, you can get more DCIR values in the same time frame.

 

But be careful with 1000Hz when you use BTS9000 for long time life-cycle test, if you accidently set 1000Hz as the data record parameter, the testing result could be crazily huge even after a short time.

How the BTS 9000 make us believed in a short time

Continue to know the specifications

Online consulting